Influence of stent design on 1-year outcome after coronary stent placement: A randomized comparison of five stent types in 1,147 unselected patients

Author(s):  
Adnan Kastrati ◽  
Josef Dirschinger ◽  
Peter Boekstegers ◽  
Shpend Elezi ◽  
Helmut Sch�hlen ◽  
...  
Author(s):  
Goo-Yeong Cho ◽  
Cheol Whan Lee ◽  
Myeong-Ki Hong ◽  
Jae-Joong Kim ◽  
Seong-Wook Park ◽  
...  

2021 ◽  
Vol 20 (1) ◽  
Author(s):  
Joseph Robert Stevens ◽  
Ava Zamani ◽  
James Ian Atkins Osborne ◽  
Reza Zamani ◽  
Mohammad Akrami

Abstract Background Coronary stents are routinely placed in the treatment and prophylaxis of coronary artery disease (CAD). Current coronary stent designs are prone to developing blockages: in-stent thrombosis (IST) and in-stent re-stenosis (ISR). This is a systematic review of the design of current coronary stent models, their structural properties and their modes of application, with a focus on their associated risks of IST and ISR. The primary aim of this review is to identify the best stent design features for reducing the risk of IST and ISR. To review the three major types of stents used in clinical settings today, determining best and relevant clinical practice by exploring which types and features of offer improved patient outcomes regarding coronary angioplasty. This information can potentially be used to increase the success rate of coronary angioplasty and stent technology in the future taking into account costs and benefits. Methods Scientific databases were searched to find studies concerning stents. After the exclusion criteria were applied, 19 of the 3192 searched literature were included in this review. Studies investigating three major types of stent design were found: bare-metal stents (BMS), drug-eluting stents (DES) and bioresorbable stents (BRS). The number of participants varied between 14 and 1264. On average 77.4% were male, with a mean age of 64 years. Results From the findings of these studies, it is clear that DES are superior in reducing the risk of ISR when compared to BMS. Conflicting results do not clarify whether BRS are superior to DES at reducing IST occurrence, although studies into newer BRS technologies show reducing events of IST to 0, creating a promising future for BRS showing them to be non-inferior. Thinner stents were shown to reduce IST rates, due to better re-endothelialisation. Scaffold material has also been shown to play a role with cobalt alloy stents reducing the risk of IST. This study found that thinner stents that release drugs were better at preventing re-blockages. Some dissolvable stents might be better at stopping blood clots blocking the arteries when compared to metal stents. The method and procedure of implanting the stent during coronary angioplasty influences success rate of these stents, meaning stent design is not the only significant factor to consider. Conclusions Positive developments in coronary angioplasty could be made by designing new stents that encompass all the most desirable properties of existing stent technology. Further work is needed to investigate the benefits of BRS in reducing the risk of IST compared to DES, as well as to investigate the effects of different scaffold materials on IST and ISR outcomes.


2020 ◽  
Vol 9 (4) ◽  
Author(s):  
Sanket S. Dhruva ◽  
Craig S. Parzynski ◽  
Ginger M. Gamble ◽  
Jeptha P. Curtis ◽  
Nihar R. Desai ◽  
...  

Author(s):  
Gianfranco Calogiuri ◽  
Eustachio Nettis ◽  
Alessandro Mandurino-Mirizzi ◽  
Elisabetta Di Leo ◽  
Luigi Macchia ◽  
...  

The anti-IgE Omalizumab may be helpful to treat clopidogrel hypersensitivity without stopping thienopyridine administration in patients requirining continuous antiplatellet therapy after coronary stent placement.


2011 ◽  
Vol 45 (10) ◽  
pp. 1307-1307 ◽  
Author(s):  
Sarah R Peppard ◽  
Bethanne M Held-Godgluck ◽  
Richard Beddingfield

Objective: To report a case of successful use of prasugrel following percutaneous coronary intervention with placement of a bare metal stent in a patient with a documented hypersensitivity reaction to clopidogrel. Case Summary: A 61-year-old male with a history of coronary artery disease with coronary stent placement presented with ST-elevation myocardial infarction. The patient had developed Stephens-Johnson syndrome 6 years earlier following Clopidogrel administration, characterized by erythematous plaques and subsequent desquamation of the hands and feet; Clopidogrel was discontinued and he was subsequently treated with ticlopidine in addition to aspirin. The third-generation thienopyridine prasugrel was initiated as a therapeutic alternative to Clopidogrel after placement of a bare metal stent; a 60-mg dose was administered after extubation, followed by 10 mg/day. No signs of allergic reaction were observed in the days, weeks, and months following administration. Discussion: Thienopyridines, specifically Clopidogrel, are the standard of care for prevention of coronary stent thrombosis; however, there are few data available on cross-hypersensitivity between these agents. One study demonstrated that 27% of patients who developed an allergic or hematologic reaction to Clopidogrel developed a similar reaction to ticlopidine. Other therapeutic options for patients with Clopidogrel hypersensitivity who are undergoing a percutaneous coronary intervention with stent placement include Clopidogrel desensitization, warfarin plus aspirin, cilostazol, ticagrelor, and ticlopidine. However, these options are limited by efficacy and/or toxicity. With its approval in 2009, prasugrel has become a potential treatment option. Conclusions: Prasugrel may be considered a therapeutic alternative in some patients allergic or intolerant to Clopidogrel, but additional data are warranted to make a strong conclusion.


2008 ◽  
Vol 264 (5) ◽  
pp. 472-480 ◽  
Author(s):  
N. Sarafoff ◽  
G. Ndrepepa ◽  
J. Mehilli ◽  
K. Dörrler ◽  
S. Schulz ◽  
...  

2004 ◽  
Vol 34 (3) ◽  
pp. 235-241 ◽  
Author(s):  
Mikio Usui ◽  
Manabu Miyagi ◽  
Shinya Fukasawa ◽  
Takeshi Hara ◽  
Naoya Ueyama ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document